| Connection Systems Fold up stop end |
![]() |
|||||||||||||||||||||
|
In principle, gutter stop ends can also be soldered in a similar way to gutter connections. However, with TECU®-Patina gutters, it is easier to use folded stop ends because possible discoloration is avoided from the outset.
|
|||||||||||||||||||||
![]() |
![]() |
![]() |
||||||||||||||||||||
Cut approx. 5 mm off the lip and wall-side fold |
Knock on the stop end |
|||||||||||||||||||||
![]() |
![]() |
|||||||||||||||||||||
Squeeze the fold closed with pliers |
Then knock over the fold parallel to the gutter |
|||||||||||||||||||||